Output signal TEMP-SIG (temperature signal)
Fault in the dataset constant FLEXO_TEMP_SIG_SETTING_

Description
Effects on the driving operation
Possible causes
Connector pin assignment of the transmission control unit
Location
Instruction
Setting conditions for the event
Test conditions for the event
Final function check
See also:
 Print page

Description

Fault in the dataset constant FLEXO_TEMP_SIG_SETTING_

Effects on the driving operation

The oil temperature warning lamp (output signal) cannot be activated anymore.

The reduction of the retarder function due to overtemperature cannot be indicated anymore.

Possible causes

Dataset parameter FLEXO_TEMP_SIG_SETTING_ contains a faulty or invalid value.

Connector pin assignment of the transmission control unit

 
PinStecker AStecker BStecker CStecker D
1SHIELDEKFLEXI-1-BATT
2TIM+DK---IGN
3TIM-SKFLEXI-3FLEXI-11
4N1+RBKFLEXI-4K-LINE
5N1-TBFLEXI-5CAN1-H
6N2+---FLEXI-6CAN1-H
7N2-RBGFLEXI-7CAN-SHLD
8N3+PBFLEXI-8CAN1-L
9N3-WRFLEXI-9CAN1-L
10---WPFLEXI-10CAN2-H
11------FLEXO-2HCAN2-H
12EKMFLEXI-12FLEXO-4HCAN2-L
13DKMS-GNDFLEXO-3HCAN2-L
14SKMOIL-LVLFLEXO-5LCAN1-R
15PBMT-SUMP------
16TBM------FLEXO-1L
17RBKMT-CONV---CAN2-R
18MVM-GNDMV-GND---+BATT

Location

Dataset

Instruction

Correct value of the dataset parameter FLEXO_TEMP_SIG_SETTING_ or load a new dataset.

Setting conditions for the event

No description available.

Test conditions for the event

No description available.

Final function check

If the defective component cannot be clearly identified, you should try to reproduce the fault:

  • Reinstall the component in the vehicle.
  • Test the function.

After the fault has been eliminated, the following steps have to be carried out:

  • Conduct a test drive with function check.
  • Read out the fault memory.
  • Check the transmission for leaks.
  • Perform a final visual inspection.

These steps are necessary to ensure the entire vehicle functions.

See also:

Aftersales service index


© by Voith Turbo GmbH & Co. KG, S. Brunnengräber
send remarks to stefan.brunnengraeber@voith.com (documentation department)