Description Overvoltage Uref
Effects on the driving operation Driving operation restricted. Frequency measurement and temperature measurement non-functional.
Possible causes The voltage regulator for 12V constant voltage operates outside the allowed tolerance.
Place of action Transmission control unit
Instruction Replace transmission control unit.
Setting conditions of the event Supply voltage > 16V, Uref > 12.5V for at least 100ms.
Test conditions of the event No description available.
Final function check If the defective component cannot be clearly identified, you should try to reproduce the fault:
After the fault has been eliminated, the following steps have to be carried out:
These steps are necessary to ensure the entire vehicle functions. See also:
| |||||||||