Description Incorrect fuel consumption via CAN.
Effects on the driving operation The operating data do not contain any information on the fuel consumption.
Possible causes An incorrect value for the fuel consumption was received on the CAN bus. Using the SAE J1939 CAN protocol: CAN message "Liquid fuel consumption (LFC)": Signal "total fuel used" (spn 250) possibly faulty.
Place of action No description available.
Instruction Check cable / plug connections Check external control unit Using the SAE J1939 CAN protocol: CAN message "Liquid fuel consumption (LFC)": Check "total fuel used" (spn 250) signal.
Setting conditions of the event No description available.
Test conditions of the event No description available.
Final function check If the defective component cannot be clearly identified, you should try to reproduce the fault:
After the fault has been eliminated, the following steps have to be carried out:
These steps are necessary to ensure the entire vehicle functions. See also:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||