Description Timeout of CAN message ID 592.
Effects on the driving operation ANS (automatic neutral at standstill) may not be available. Kick-down not available. Speed plausibility check non-functional, therefore driving may not be possible.
Possible causes FMR controller defective or connection to FMR controller faulted.
Place of action No description available.
Troubleshooting
Check FMR controller and connection to FMR controller.
Setting conditions of the event No description available.
Test conditions of the event No description available.
Final function check If the defective component cannot be clearly identified, you should try to reproduce the fault:
After the fault has been eliminated, the following steps have to be carried out:
These steps are necessary to ensure the entire vehicle functions. See also:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||