Step backTable of contents

CAN Protocol VOITH private CAN
Timeout of message InputValues1

Description
Effects on the driving operation
Possible causes
Place of action
Instruction
Setting conditions of the event
Test conditions of the event
Final function check
See also:
 Print page

Description

Timeout of CAN message INPUT VALUES 1.

Effects on the driving operation

Functions using the flexible inputs of the gear range selector are not available.

Possible causes

Communication to the gear selector is disturbed or gear selector defective.

Incorrect voltage supply of the gear range selector.

Place of action

No description available.

Instruction

Check communication to the gear selector and the gear selector itself.

Check voltage supply of the gear range selector.

Setting conditions of the event

No description available.

Test conditions of the event

No description available.

Final function check

If the defective component cannot be clearly identified, you should try to reproduce the fault:

  • Reinstall the component in the vehicle.
  • Test the function.

After the fault has been eliminated, the following steps have to be carried out:

  • Conduct a test drive with function check.
  • Read out the fault memory.
  • Check the transmission for leaks.
  • Perform a final visual inspection.

These steps are necessary to ensure the entire vehicle functions.

See also:

CAN SAE J1939 Voith specifics (SW E300-D2.3.0.0)
CAN SAE J1939 Voith specifics (SW E300-D2.4.0.0)
Aftersales service index


© by Voith Turbo GmbH & Co. KG, S. Brunnengräber
send remarks to stefan.brunnengraeber@voith.com (documentation department)