Step backTable of contents

Shift program
Short-circuit or low-resistance connection to supply voltage at the digital input "SP selector"

Description
Effects on the driving operation
Possible causes
Location
Instruction
Setting conditions for the event
Test conditions for the event
Final function check
See also:
 Print page

Description

Short-circuit or low-resistance connection to supply voltage at the digital input "SP selector".

Effects on the driving operation

No changing of the shifting program possible.

Possible causes

Short-circuit or low-resistance connection of the input to supply voltage.

Location

No description available.

Instruction

Check plug connections and cabling.

Setting conditions for the event

No description available.

Test conditions for the event

No description available.

Final function check

If the defective component cannot be clearly identified, you should try to reproduce the fault:

  • Reinstall the component in the vehicle.
  • Test function.

After the fault has been eliminated, the following steps have to be carried out:

  • Conduct a test drive with function check.
  • Read the fault memory
  • Check transmission for leaks.
  • Perform a final visual inspection.

These steps are necessary to ensure the entire vehicle functions correctly.

See also:

Troubleshooting for short-circuit to 24 V
Aftersales service index


© by Voith Turbo GmbH & Co. KG, S. Brunnengräber
send remarks to stefan.brunnengraeber@voith.com (documentation department)