Description The safety computer has detected undervoltage in the driving mode.
Effects on the driving operation The solenoid valves cannot be activated until the voltage of the electric system is stable again. If the voltage of the electric system has return to normal, it is necessary to engage neutral first before another gear request is accepted.
Possible causes The voltage of the electric system is unstable.
Place of action No description available.
Instruction Check voltage of the vehicle’s electric system.
Setting conditions of the event No description available.
Testing conditions of the event No description available.
Final function check If the defective component cannot be clearly identified, you should try to reproduce the fault:
After the fault has been eliminated, the following steps have to be carried out:
These steps are necessary to ensure the entire vehicle functions correctly. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||