Code 020160 — Central solenoid valve handler — Solenoid valve supply voltage too low.

Procedure

1 Check the on-board voltage

Check the on-board voltage

1. Controller pin assignment

2. Pushbutton selector pin assignment

Procedure

  1. Using a voltmeter, check the voltage between +BATT / -BATT and
    between IGN / -BATT on the controller.

  2. Using a voltmeter, check the voltage between IGN / -BATT on the pushbutton selector.

Top of Page