Terminal connection diagram

Test steps

  • If the lighting of the gear selector switch is defective, replace the defective light bulb.
  • Open plug connection S2.
    Depending on what fault is displayed by the diagnosis, apply button (switch) according to the following table and measure resistance between contacts.
    If all measurements yield R = RTarget, continue with point 4.
Button, switchS2: Measure between +TL and:RTarget [Ω]: Pushbutton depressed/not depressed
121 (-UB)approx. 580
221 (-UB)approx. 580
321 (-UB)approx. 580
D21 (-UB)approx. 580
N21 (-UB)approx. 580
R21 (-UB)approx. 580
Rev. inh. approx. 580

 

Button, switchS2: Measure betw. contact 29 (TS) and:RTarget [Ω]: Pushbutton depressed (N depressed) [N not depressed]
110 (/N)0 (∞)
210 (/N)0 (∞)
310 (/N)0 (∞)
D10 (/N)0 (∞)
N10 (/N)∞ [0]
R10 (/N)0 (∞)
Rev. inh.  

 

Button, switchS2: Measure betw. contact 29 (TS) and:RTarget [Ω]: Pushbutton depressed (not depressed)
127 (S1)0 (∞)
245 (S2)0 (∞)
39 (S3)0 (∞)
D28 (+V)0 (∞)
N  
R46 (+R)0 (∞)
Rev. inh.30 (RS)0 (∞)*

*= Resistance value with R pushbutton depressed simultaneously

  • Open S7.
    Depending on what fault is displayed by the diagnosis, apply pushbutton (switch) according to the following table and measure resistance between contacts.
Button, switchMeasure between +TL and:RTarget [Ω]: Pushbutton depressed/not depressed
110 (-UB)approx. 580
210 (-UB)approx. 580
310 (-UB)approx. 580
D10 (-UB)approx. 580
N10 (-UB)approx. 580
R10 (-UB)approx. 580
Rev. inh.  

 

Button, switchMeasure betw. contact 29 (TS) and:RTarget [Ω]: Pushbutton depressed (N depressed) [N not depressed]
111 (SSP)∞ (0)
211 (SSP)∞ (0)
311 (SSP)∞ (0)
D11 (SSP)∞ (0)
N11 (SSP)0 [∞]
R11 (SSP)0 (∞)
Rev. inh.  

 

Button, switchMeasure betw. contact 7 (TS) and:RTarget [Ω]: Pushbutton depressed (N not depressed)
19 (/N)0 (∞)
29 (/N)0 (∞)
39 (/N)0 (∞)
D9 (/N)0 (∞)
N9 (/N)∞ [0]
R9 (/N)0 (∞)
Rev. inh.  

 

Button, switchMeasure betw. contact 7 (TS) and:RTarget [Ω]: Pushbutton depressed (not depressed)
11 (S1)0 (∞)
22 (S2)0 (∞)
33 (S3)0 (∞)
D4 (+V)0 (∞)
N  
R5 (+R)0 (∞)
Rev. inh.6 (RS)0 (∞)*

 

  • Check resistance to ground: S2, contacts 9,10, 21, 27, 28, 29, 30,33, 45, 46.
    RTarget = ∞ Ω.

Notice: variable signal

The assignment to a connection of the transmission control unit is accomplished in the data record and is vehicle-specific.