Step backTable of contents

Turbine speed sensor
Fault while measuring the sensor voltage

Description
Effects on the driving operation
Possible causes
Place of action
Instruction
Setting conditions of the event
Test conditions of the event
Final function check
See also:
 Print page

Description

Fault while measuring the sensor voltage

Effects on the driving operation

Hard retarder activation

No braking in first gear (no braking with RBK disks)

Possible causes

Error while reading the sensor voltages U(nA) or U(nB). The fault is probably located inside the control unit.

Place of action

Transmission control unit

Instruction

Replace transmission control unit.

Setting conditions of the event

No description available.

Test conditions of the event

No description available.

Final function check

If the defective component cannot be clearly identified, you should try to reproduce the fault:

  • Reinstall the component in the vehicle.
  • Test the function.

After the fault has been eliminated, the following steps have to be carried out:

  • Conduct a test drive with function check.
  • Read out the fault memory.
  • Check the transmission for leaks.
  • Perform a final visual inspection.

These steps are necessary to ensure the entire vehicle functions.

See also:

Aftersales service index


© by Voith Turbo GmbH & Co. KG, S. Brunnengräber
send remarks to stefan.brunnengraeber@voith.com (documentation department)