Description Undiagnosible fault
Effects on the driving operation Unable to detect temperature, possible consequences: The temperature-related deactivation of the retarder is restricted.
Possible causes The cause could be a cable break or short-circuit to supply voltage. If the error 'Reference voltage too high' is also present, this indicates a short-circuit to supply voltage. If only one temperature sensor reports this fault, there is probably a cable break at this sensor.
Location No description available.
Instruction Check plug-in contacts, cabling and sensor.
Setting conditions of the event No description available.
Test conditions of the event No description available. See also:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||