Step backTable of contents

CAN gear range selector E330
Fault in the CAN-communication of the CAN gear selector switch

Description
Effects on the driving operation
Possible causes
Place of action
Instruction
Setting conditions of the event
Test conditions of the event
Final function check
See also:
 Print page

Description

A fault has occurred during communication with the gear range selector: The gear range selector does not respond to the command.

Effects on the driving operation

None.

Possible causes

No Voith gear range selector available.

Communication to the gear range selector is disturbed.

Gear range selector defective.

Control unit defective.

Place of action

No description available.

Instruction

Is a Voith gear range selector really installed? If not, check dataset value CAN_CONTROLLER_NUMBER_PUBLIC_CAN.

Check communication to the gear range selector.

Check gear range selector.

Check control unit.

Setting conditions of the event

No description available.

Test conditions of the event

No description available.

Final function check

If the defective component cannot be clearly identified, you should try to reproduce the fault:

  • Reinstall the component in the vehicle.
  • Test the function.

After the fault has been eliminated, the following steps have to be carried out:

  • Conduct a test drive with function check.
  • Read out the fault memory.
  • Check the transmission for leaks.
  • Perform a final visual inspection.

These steps are necessary to ensure the entire vehicle functions.

See also:

Aftersales service index


© by Voith Turbo GmbH & Co. KG, S. Brunnengräber
send remarks to stefan.brunnengraeber@voith.com (documentation department)