Step backTable of contents

Software module Event memory
Fault in dataset

Description
Effects on the driving operation
Possible causes
Place of action
Troubleshooting
Instruction
Setting conditions of the event
Test conditions of the event
Final function check
See also:
 Print page

Description

The data dataset value EVENTMEM_TIME_UNTIL_DELETE_ is incorrectly set to 0.

The event memory would be cleared as a consequence after each system start.

Therefore, the software has blocked the automatic, time-dependent clearing

Effects on the driving operation

The software has blocked the automatic, time-dependent deletion of the data.

Possible causes

Faulty dataset or dataset value EVENTMEM_TIME_UNTIL_DELETE_ was modified illegally.

Place of action

No description available.

Troubleshooting


NOTE

The following service work may only be performed by persons who are authorised by the vehicle manufacturer:

  • Loading software and/or datasets into the transmission control unit.
  • Service work at vehicle components which are not included in the VOITH delivery.


Instruction

Load appropriate dataset.

Setting conditions of the event

No description available.

Test conditions of the event

No description available.

Final function check

If the defective component cannot be clearly identified, you should try to reproduce the fault:

  • Reinstall the component in the vehicle.
  • Test the function.

After the fault has been eliminated, the following steps have to be carried out:

  • Conduct a test drive with function check.
  • Read out the fault memory.
  • Check the transmission for leaks.
  • Perform a final visual inspection.

These steps are necessary to ensure the entire vehicle functions.

See also:

Aftersales service index


© by Voith Turbo GmbH & Co. KG, S. Brunnengräber
send remarks to stefan.brunnengraeber@voith.com (documentation department)