Monitoring of the safety computer (by the main computer)
Solenoid valve voltage incorrect

Description
Effects on the driving operation
Possible causes
Place of action
Instruction
Setting conditions of the event
Test conditions of the event
Final function check
See also:
 Print page

Description

The safety computer does not detect the solenoid valve voltages correctly.

Effects on the driving operation

Driving is not possible.

Possible causes

efective solenoid valve plug connections.

Defective solenoid valve wiring.

Defective solenoid valve

Internal fault of the safety computer

Internal fault of the control unit

Place of action

No description available.

Instruction

Check plug connections and cabling of solenoid valves.

Clear event memory

If the fault can not be eliminated, please contact the VOITH customer service.

Setting conditions of the event

No description available.

Test conditions of the event

No description available.

Final function check

If the defective component cannot be clearly identified, you should try to reproduce the fault:

  • Reinstall the component in the vehicle.
  • Test the function.

After the fault has been eliminated, the following steps have to be carried out:

  • Conduct a test drive with function check.
  • Read out the fault memory.
  • Check the transmission for leaks.
  • Perform a final visual inspection.

These steps are necessary to ensure the entire vehicle functions.