Description Time signal 'Day' within the CAN message 'Time/Date' faulty (CAN SPN 962).
Effects on the driving operation Entries in the event memory contain no or faulty 'Time/Date identification'.
Possible causes An incorrect value for 'Day' within the CAN message 'Time/Date' was received via the CAN bus (CAN SPN 962). With software version D2.3.0.0: With this version of the transmission control unit software, the message occurs on the 1st of each month. The reason is a wrong calculation of the day number. This has no effect on the driving operation and can be ignored. Some of the time flags in the event memory might be set incorrectly.
Place of action No description available.
Instruction Check CAN message 'Time/Date' on the CAN bus and make it available if necessary (if SAE J1939 CAN protocol is used).
Setting conditions of the event No description available.
Test conditions of the event No description available.
Final function check If the defective component cannot be clearly identified, you should try to reproduce the fault:
After the fault has been eliminated, the following steps have to be carried out:
These steps are necessary to ensure the entire vehicle functions. See also:
| |||||||||
© by Voith Turbo GmbH & Co. KG, S. Brunnengräber send remarks to stefan.brunnengraeber@voith.com (documentation department) | |||||||||