Description Communication on the CAN bus fails due to CAN ´bus off´ conditions. 'bus off' : If the error counter of a CAN controller exceeds the value 255, the CAN controller will assume the 'bus off' status. The CAN controller is disconnected from the CAN bus using an internal logic function and does no longer participate in the bus activities. CAN messages can no longer be received nor sent.
Effects on the driving operation No CAN communication via CAN controller 2 of the transmission control unit possible. Vehicle does not drive or only with restrictions.
Possible causes Short-circuit between CAN-H and CAN-L or short-circuit of a CAN line to ground. * A bus node is sending with incorrect bit rate. * Another defective control unit is connected to the CAN bus. * Defective CAN transceiver in the E300 control unit.
Connector pin assignment of transmission control unit
Place of action CAN-Bus 2
Troubleshooting
Measure resistance between CAN-H and CAN-L ( ~ 60 ohms). Check cabling. * Measure resistance between CAN-H and CAN-L to ground. The resistance must lie well above 1 kohm. * Check whether the correct dataset and correct CAN protocol are active. * Disconnect all control units from the CAN bus one after the other and check whether this eliminates the fault. * Replace E300 control unit.
Setting conditions of the event No description available.
Test conditions of the event No description available.
Final function check If the defective component cannot be clearly identified, you should try to reproduce the fault:
After the fault has been eliminated, the following steps have to be carried out:
These steps are necessary to ensure the entire vehicle functions. See also:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
© by Voith Turbo GmbH & Co. KG, S. Brunnengräber send remarks to stefan.brunnengraeber@voith.com (documentation department) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||