Description Faulty retarder limit.
Effects on the driving operation The retarder is not limited / shut down (e.g. by the ABS system).
Possible causes The retarder torque limit requested via CAN is faulty. The source causing the fault can be found in the system description.
Place of action No description available.
Instruction Check the CAN-message and contact the manufacturer of the transmitting control unit if necessary. (With SAE J1939: TSC1(Torque/ Speed Controller #1), 'override control mode' ;TSC1(Torque/ Speed Controller #1), 'requested torque' ).
Setting conditions of the event No description available.
Testing conditions of the event No description available.
Final function check If the defective component cannot be clearly identified, you should try to reproduce the fault:
After the fault has been eliminated, the following steps have to be carried out:
These steps are necessary to ensure the entire vehicle functions correctly. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
© by Voith Turbo GmbH & Co. KG, S. Brunnengräber send remarks to stefan.brunnengraeber@voith.com (documentation department) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||