<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<ip:DiagnosticMemory xmlns:ip="http://man.eu/mancats3/diagnosespeicher" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" DataFormat="0001" FileType="Diagnosespeicher" schema-version="2.10" xsi:schemaLocation="http://man.eu/mancats3/trenddaten Diagnosespeicher.xsd">
    <ip:Header>
        <ip:MANcats-Version Value="V20_11"/>
        <ip:WID Value="WID33570"/>
        <ip:FP Value="030053ED"/>
        <ip:Timestamp day="22" hour="16" mileage="728240" minute="26" month="08" operatinghour="" second="03" year="2020"/>
    </ip:Header>
    <ip:VehicleInformation>
        <ip:LicensePlateNumber Value="Nicht eingetragen" default-label="Kfz-Kennzeichen" stringResource-OID="SRs_XYGMLB37HIUDZMQW5"/>
        <ip:FirstRegistrationDate Value="1333376528940" default-label="Erstzulassungsdatum" stringResource-OID="SRs_XXRU5UQ0IEJBAPM69"/>
        <ip:NumberOfECUs Value="17"/>
        <ip:ShortVin Value="05X7855" default-label="Kurze VIN" stringResource-OID="SRs_X66Z0JBEHLQ64B0JH"/>
        <ip:LongVin Value="WMA05XZZXCM596021" default-label="Lange Fahrgestellnummer" stringResource-OID="SRs_XJOD1JBEHQQETUTJL"/>
        <ip:VEC Value="TGX_TGS"/>
    </ip:VehicleInformation>
    <ip:KWP_ECUs>
        <ip:ECU AuthoringEcuName="AKS-ACC-MAN">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25805.7206" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="1">
                <ip:DTC default-label="Czujnik magistrali CAN komunikat ESP" stringResource-OID="SRs_XV99DQR7HUF5MPV0A" value="4569">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="04" hour="08" mileage="714190.81" minute="41" month="07" operatinghour="" second="01" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3004" default-label="Zusatzinformation 4" stringResource-OID="Zusatzinformation 4"/>
                            <ip:data Value="0" unit="km/h"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="3003" default-label="Zusatzinformation 3" stringResource-OID="Zusatzinformation 3"/>
                            <ip:data Value="0" unit="m"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="3002" default-label="Zusatzinformation 2" stringResource-OID="Zusatzinformation 2"/>
                            <ip:data Value="129" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="3001" default-label="Zusatzinformation 1" stringResource-OID="Zusatzinformation 1"/>
                            <ip:data Value="0" unit="km/h"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="AKS-TBM-OHB">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25812-7022" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="AKS-LGS-Iteris">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25813-7005" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="1">
                <ip:DTC default-label="Błąd urządzenia sterującego" stringResource-OID="SRs_XB57FMR7H4UFTVYEJ" value="3004">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="4"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="06" hour="16" mileage="724179.56" minute="51" month="08" operatinghour="" second="44" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="AKS-TPM-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25813-7004" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="3">
                <ip:DTC default-label="Ciśnienie opon" stringResource-OID="SRs_XTPU93X7HLLHUKFRB" value="3000">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="4"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="25" hour="07" mileage="720175.69" minute="45" month="07" operatinghour="" second="59" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="SRs_X5SMLKIOHRSBEAKYA" default-label="Przebieg w kilometrach" stringResource-OID="SRs_XEHPET9EHA6620M3D"/>
                            <ip:data Value="720175.69" unit="km"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Ciśnienie w oponie osi 2 po lewej stronie, wewnątrz" stringResource-OID="SRs_XYGV93X7H3YOSO4N2" value="3022">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="4"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="25" hour="07" mileage="720175.69" minute="45" month="07" operatinghour="" second="58" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="SRs_X5SMLKIOHRSBEAKYA" default-label="Przebieg w kilometrach" stringResource-OID="SRs_XEHPET9EHA6620M3D"/>
                            <ip:data Value="720175.69" unit="km"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Ciśnienie w oponie osi 2 po prawej stronie wewnątrz" stringResource-OID="SRs_XRJV93X7HCZ6UI7Z7" value="3023">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="4"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="25" hour="07" mileage="720175.69" minute="45" month="07" operatinghour="" second="59" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="SRs_X5SMLKIOHRSBEAKYA" default-label="Przebieg w kilometrach" stringResource-OID="SRs_XEHPET9EHA6620M3D"/>
                            <ip:data Value="720175.69" unit="km"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="KLM-BHTC-Behr">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25814-7015" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="FWK-ECAS2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25811-7024" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-ZBR2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25806-7105" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="3">
                <ip:DTC default-label="Suwy pompy centralnego układu smarowania" stringResource-OID="SRs_XHX2Q5D1HZ338925E00" value="4402">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="4" default-label="Brak sygnału" stringResource-OID="SRs_XFKLTIIOHW8NPT4HW"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="06" mileage="708122.56" minute="55" month="06" operatinghour="" second="23" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="22" hour="14" mileage="728240.31" minute="24" month="08" operatinghour="" second="51" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Usterka ABS przyczepy" stringResource-OID="SRs_XNCKQ5D1HZD38925E00" value="3500">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="08" hour="12" mileage="715117.31" minute="31" month="07" operatinghour="" second="56" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="13" hour="10" mileage="726327.94" minute="48" month="08" operatinghour="" second="14" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Lewe światło mijania" stringResource-OID="SRs_XNK9S5D1H8D38925E00" value="4001">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="12" default-label="Przerwanie lub zwarcie do Ubat" stringResource-OID="SRs_XYQ2SIIOHQ5F1E9YA"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="8"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="20" hour="06" mileage="727779.25" minute="15" month="08" operatinghour="" second="19" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="21" hour="12" mileage="728240.31" minute="21" month="08" operatinghour="" second="31" year="2020"/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="BRM-EBS5-Knorr">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25808-7066" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="3">
                <ip:DTC default-label="Czujnik okładziny hamulcowej – żądanie – lampa ostrzegawcza" stringResource-OID="SRs_XXC72VZ9HOJQMVB11" value="3515">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="6"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="23" hour="07" mileage="719698.25" minute="13" month="07" operatinghour="" second="24" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="23" hour="07" mileage="21474836" minute="13" month="07" operatinghour="" second="63" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Czujnik okładziny hamulcowej – oś tylna 1/oś przednia 2, po lewej stronie – koło 3 – różnica sygnałów" stringResource-OID="SRs_XS6XPOZ9HAXYMYXV" value="4601">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="25" hour="07" mileage="720175.69" minute="46" month="07" operatinghour="" second="43" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="25" hour="07" mileage="21474836" minute="46" month="07" operatinghour="" second="63" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Czujnik okładziny hamulcowej – oś tylna 1/oś przednia 2 po lewej stronie – koło 3 – kontrola sygnałów" stringResource-OID="SRs_XS995VZ9HKUJ696TH" value="4509">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="26"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="13" hour="13" mileage="726330.5" minute="33" month="08" operatinghour="" second="36" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="13" hour="13" mileage="21474836" minute="33" month="08" operatinghour="" second="63" year="2020"/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="HZG-AirTRNC-EBSPR">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25814-6041" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="AKS-UHV-FUNKW">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25812-7020" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="AKS-TuerMOD-TRW">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25806-7092" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="INS-Inst-STON">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25807.7120" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="GTR-Astronic-ZF">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25809-7685" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="1">
                <ip:DTC default-label="Grupa preselekcyjna – przełączanie mechaniczne" stringResource-OID="SRs_XQ6A3W41HCP38925E00" value="3149">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="2" default-label="Potencjalnie możliwy błąd" stringResource-OID="SRs_XQUJREIOHU132A8UI"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="3"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="13" hour="09" mileage="726296.38" minute="52" month="08" operatinghour="" second="30" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="MOT-EDC7C32-Bosch">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="51.25803-7668" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
    </ip:KWP_ECUs>
    <ip:UDS_ECUs>
        <ip:ECU AuthoringEcuName="RET-InTRDR3-ZF">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0xF187" Value="81.25810-7012" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer Spare Part Number#PA_DataRecor.PA_VehicManufSparePartNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="2">
                <ip:DTC default-label="Urządzenie sterujące – intarder IT3 – temperatura otoczenia" stringResource-OID="SRs_XUL268X7HTST8E487" value="4222">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_XL8EOEIOHE14S3PYE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="12" default-label="Przerwanie lub zwarcie do Ubat" stringResource-OID="SRs_XYQ2SIIOHQ5F1E9YA"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="21"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="17" hour="08" mileage="708642.94" minute="53" month="06" operatinghour="" second="14" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Wyjściowa prędkość obrotowa przekładnika" stringResource-OID="SRs_X4S635V9HY46ELG1N"/>
                            <ip:data Value="28" unit="rpm"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Prędkość obrotowa napędu" stringResource-OID="SRs_XSGDIB73I0Q189QXN"/>
                            <ip:data Value="972.3" unit="rpm"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Napięcie zacisku 30" stringResource-OID="SRs_X4EZYV41HRG38925E00"/>
                            <ip:data Value="0" unit="V"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="9767" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Ogranicznik momentu, moment zadany" stringResource-OID="SRs_XT0XFS35HAH43C3810A"/>
                            <ip:data Value="0" unit="Nm"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="17" hour="04" mileage="726530.25" minute="24" month="08" operatinghour="" second="18" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Wyjściowa prędkość obrotowa przekładnika" stringResource-OID="SRs_X4S635V9HY46ELG1N"/>
                            <ip:data Value="28.3" unit="rpm"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Prędkość obrotowa napędu" stringResource-OID="SRs_XSGDIB73I0Q189QXN"/>
                            <ip:data Value="1164.4" unit="rpm"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Napięcie zacisku 30" stringResource-OID="SRs_X4EZYV41HRG38925E00"/>
                            <ip:data Value="0" unit="V"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="11616" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Ogranicznik momentu, moment zadany" stringResource-OID="SRs_XT0XFS35HAH43C3810A"/>
                            <ip:data Value="0" unit="Nm"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Sygnał CAN &quot;Tachograph Output Shaft Speed (tachograf, prędkość wału wyjściowego)&quot; TCO1" stringResource-OID="SRs_X3L268X7HES71P5GR" value="1623">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_XL8EOEIOHE14S3PYE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="4" default-label="Brak sygnału" stringResource-OID="SRs_X6CA58BAHNKS75EM4"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="04" hour="08" mileage="714190.81" minute="41" month="07" operatinghour="" second="02" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Wyjściowa prędkość obrotowa przekładnika" stringResource-OID="SRs_X4S635V9HY46ELG1N"/>
                            <ip:data Value="24.7" unit="rpm"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Prędkość obrotowa napędu" stringResource-OID="SRs_XSGDIB73I0Q189QXN"/>
                            <ip:data Value="0" unit="rpm"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Napięcie zacisku 30" stringResource-OID="SRs_X4EZYV41HRG38925E00"/>
                            <ip:data Value="0" unit="V"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="4096" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Ogranicznik momentu, moment zadany" stringResource-OID="SRs_XT0XFS35HAH43C3810A"/>
                            <ip:data Value="0" unit="Nm"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="04" hour="08" mileage="714190.81" minute="50" month="07" operatinghour="" second="23" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Wyjściowa prędkość obrotowa przekładnika" stringResource-OID="SRs_X4S635V9HY46ELG1N"/>
                            <ip:data Value="24.2" unit="rpm"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Prędkość obrotowa napędu" stringResource-OID="SRs_XSGDIB73I0Q189QXN"/>
                            <ip:data Value="0" unit="rpm"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Napięcie zacisku 30" stringResource-OID="SRs_X4EZYV41HRG38925E00"/>
                            <ip:data Value="0" unit="V"/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="nieużywany" stringResource-OID="SRs_X8FM83K7HD76ZITF9"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="5602" default-label="Ogranicznik momentu, moment zadany" stringResource-OID="SRs_XT0XFS35HAH43C3810A"/>
                            <ip:data Value="0" unit="Nm"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-PTM-MAN">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0xF187" Value="81.25805-7116" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer Spare Part Number#PA_DataRecor.PA_VehicManufSparePartNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="1">
                <ip:DTC default-label="Kontrola poziomu oleju silnikowego" stringResource-OID="SRs_X3LIL9X7H4KPYPA2K" value="5712">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_XL8EOEIOHE14S3PYE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="no fault symptom available for DTC" stringResource-OID="no fault symptom available for DTC"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="10" hour="17" mileage="724890.44" minute="14" month="08" operatinghour="" second="26" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="5007" default-label="Grupa funkcyjna" stringResource-OID="SRs_XR30GT9YHANUUBTZ6"/>
                            <ip:data Value="Silnik" unit=""/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="MOT-AdBlue-Bosch">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0xF187" Value="81.25819-7016" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer Spare Part Number#PA_DataRecor.PA_VehicManufSparePartNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
    </ip:UDS_ECUs>
    <ip:OBD_ECUs>
        <ip:ECU OBDEcuName="ECU_061">
            <ip:DTCs count="3">
                <ip:DTC default-label="NOx Sensor Circuit Low Input Bank 1" value="P2202">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
                <ip:DTC default-label="NOx Sensor Heater Control Circuit High Bank 1" value="P2207">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
                <ip:DTC default-label="NOx Sensor Heater Sense Circuit Range/Performance Bank 1" value="P2209">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
    </ip:OBD_ECUs>
</ip:DiagnosticMemory>