<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<ip:DiagnosticMemory xmlns:ip="http://man.eu/mancats3/diagnosespeicher" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" DataFormat="0001" FileType="Diagnosespeicher" schema-version="2.10" xsi:schemaLocation="http://man.eu/mancats3/trenddaten Diagnosespeicher.xsd">
    <ip:Header>
        <ip:MANcats-Version Value="V20_33"/>
        <ip:WID Value="WID33570"/>
        <ip:FP Value="030053ED"/>
        <ip:Timestamp day="20" hour="00" mileage="1043737" minute="17" month="09" operatinghour="" second="57" year="2020"/>
    </ip:Header>
    <ip:VehicleInformation>
        <ip:LicensePlateNumber Value="SRs_XBXHM9MAK168C5EB11" default-label="Kfz-Kennzeichen" stringResource-OID="SRs_XYGMLB37HIUDZMQW5"/>
        <ip:NumberOfECUs Value="11"/>
        <ip:ShortVin Value="A217574" default-label="Kurze VIN" stringResource-OID="SRs_X66Z0JBEHLQ64B0JH"/>
        <ip:LongVin Value="WMAA21ZZ1CR010514" default-label="Lange Fahrgestellnummer" stringResource-OID="SRs_XJOD1JBEHQQETUTJL"/>
        <ip:VEC Value="Bus_mit_TEPS"/>
    </ip:VehicleInformation>
    <ip:KWP_ECUs>
        <ip:ECU AuthoringEcuName="FZG-ZBRO-CONTI">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="1">
                <ip:DTC default-label="Awaria drzwi" stringResource-OID="SRs_XC0SSJV7H05V1P5JG" value="4673">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="CONFIRMED-AND-PASSIVE" stringResource-OID="CONFIRMED-AND-PASSIVE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="no fault symptom available for DTC" stringResource-OID="no fault symptom available for DTC"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="1"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="18" hour="01" mileage="1043514.69" minute="07" month="09" operatinghour="" second="45" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="1" default-label="Distance" stringResource-OID="Distance"/>
                            <ip:data Value="1043737.69" unit="km"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-FFR-Conti">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25805-7086" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-ZBR2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25806-7105" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="INS-Inst-STON">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25807.7094" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-KSM-MAN">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25816-7007" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="FWK-ECAS2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25811-7026" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="AKS-TuerMTS-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="36.25813-7005" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecorIdent.PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="GTR-DIWA-Voith">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="36.25809-7058" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="5">
                <ip:DTC default-label="Komunikat magistrali CAN – informacje – sygnał wejściowy ABS" stringResource-OID="SRs_XTMB7B77HS7N8EHD5" value="4614">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="3"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="9"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="18" hour="01" mileage="1043514.69" minute="13" month="09" operatinghour="" second="23" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="224" mileage="null" minute="177" month="00" operatinghour="" second="00" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Czujnik temperatury oleju przekładniowego, zestyk B15" stringResource-OID="SRs_XN197B77HJR2QC8W8" value="3002">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="9"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="18" hour="01" mileage="1043521.62" minute="23" month="09" operatinghour="" second="06" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="160" mileage="null" minute="177" month="00" operatinghour="" second="00" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Oprogramowanie w urządzeniu sterującym przekładnią" stringResource-OID="SRs_XJU38B77HYXHS0HFM" value="5532">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="9"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="18" hour="02" mileage="1043548.19" minute="28" month="09" operatinghour="" second="21" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="224" mileage="null" minute="177" month="00" operatinghour="" second="00" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Funkcja zwalniacza temperatury" stringResource-OID="SRs_XCKP7B77H4996NNR9" value="2999">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="9"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="8"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="18" hour="07" mileage="1043642.88" minute="00" month="09" operatinghour="" second="17" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="64" mileage="null" minute="177" month="00" operatinghour="" second="00" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Sygnał magistrali CAN hamulca przystankowego" stringResource-OID="SRs_X7SS8B77HV8HKY0G0" value="4713">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="3"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="18" hour="11" mileage="1043729.81" minute="10" month="09" operatinghour="" second="20" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="128" mileage="null" minute="177" month="00" operatinghour="" second="00" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="BRM-EBS2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25808-7068" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="4">
                <ip:DTC default-label="(!) Kombinacja hamulec – wieniec biegunowy – czujnik, oś przednia z prawej" stringResource-OID="SRs_XJSC8G7MHZSB8JOAE" value="3159">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="7"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="18" hour="01" mileage="1043514.69" minute="13" month="09" operatinghour="" second="23" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Wyłącznik ciśnieniowy hamulca postojowego" stringResource-OID="SRs_XZGHQ8RSI1WFSDQ5" value="3556">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="3" default-label="Niezgodne" stringResource-OID="SRs_X5RRCKIOH0POKEJFU"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="121"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="14" mileage="970277.5" minute="32" month="02" operatinghour="" second="57" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Błąd czujnika prędkości obrotowej podczas ostatniego włączania zapłonu" stringResource-OID="SRs_XSXG8G7MHWZCVZJWU" value="3519">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="19" hour="21" mileage="1043737.88" minute="22" month="09" operatinghour="" second="23" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Napięcie zasilające urządzenia sterującego (zacisk 15)" stringResource-OID="SRs_XQNG8G7MH5WR58485" value="3016">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="5"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="17" hour="20" mileage="1043514.69" minute="55" month="09" operatinghour="" second="44" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="HZG-ThermoS-SPHER">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="36.25814-6003" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="MOT-EDC7C32-Bosch">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="51.25833-7092" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="1">
                <ip:DTC default-label="Brak możliwości adaptacji sondy lambda" stringResource-OID="SRs_XA7ND0R8HJGOR7U28" value="3938">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="2" default-label="Potencjalnie możliwy błąd" stringResource-OID="SRs_XQUJREIOHU132A8UI"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="3"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="18"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="17" hour="20" mileage="1043514.69" minute="55" month="09" operatinghour="" second="15" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3961" default-label="Współczynnik korekty do adapt. stęż. tlenu" stringResource-OID="SRs_XDDX2ZQ8H8T2XC5SM"/>
                            <ip:data Value="8" unit=""/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3959" default-label="Współcz trw imp do wysterow stopnia końcowego grzejnika" stringResource-OID="SRs_XV7FD0R8H1L7WEBSR"/>
                            <ip:data Value="2" unit="%"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
    </ip:KWP_ECUs>
</ip:DiagnosticMemory>