<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<ip:DiagnosticMemory xmlns:ip="http://man.eu/mancats3/diagnosespeicher" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" DataFormat="0001" FileType="Diagnosespeicher" schema-version="2.10" xsi:schemaLocation="http://man.eu/mancats3/trenddaten Diagnosespeicher.xsd">
    <ip:Header>
        <ip:MANcats-Version Value="V20_11"/>
        <ip:WID Value="WID33570"/>
        <ip:FP Value="030053ED"/>
        <ip:Timestamp day="31" hour="11" mileage="1016433" minute="37" month="07" operatinghour="" second="42" year="2020"/>
    </ip:Header>
    <ip:VehicleInformation>
        <ip:LicensePlateNumber Value="Nicht eingetragen" default-label="Kfz-Kennzeichen" stringResource-OID="SRs_XYGMLB37HIUDZMQW5"/>
        <ip:NumberOfECUs Value="7"/>
        <ip:ShortVin Value="1111111" default-label="Kurze VIN" stringResource-OID="SRs_X66Z0JBEHLQ64B0JH"/>
        <ip:LongVin Value="WMAA21ZZ37R003893" default-label="Lange Fahrgestellnummer" stringResource-OID="SRs_XJOD1JBEHQQETUTJL"/>
        <ip:VEC Value="Bus_mit_TEPS"/>
    </ip:VehicleInformation>
    <ip:KWP_ECUs>
        <ip:ECU AuthoringEcuName="ZTR-FFR-Conti">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25805.7055" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="FZG-ZBRO-CONTI">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="MOT-EDC7C32-Bosch">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="51.25803-7376" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="8">
                <ip:DTC default-label="Ciśnienie szyny paliwowej: przeciek z powodu wyrównania ilości" stringResource-OID="SRs_XN1BD0R8HJ9HZZ6LB" value="3779">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="1"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="31" hour="09" mileage="1016433.62" minute="20" month="07" operatinghour="" second="59" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="157" default-label="Ciśnienie paliwa w szynie paliwowej" stringResource-OID="SRs_XPXAD0R8HV7JCVMB"/>
                            <ip:data Value="56848" unit="kPa"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3688" default-label="Wielk nastawcza regulat ciśn (współcz trwania impulsu)" stringResource-OID="SRs_XQ4ATWP8HUWXOSUAX"/>
                            <ip:data Value="21" unit="%"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Highside - stopień końcow ukł recyrkulacji spalin (AGR)" stringResource-OID="SRs_XYNAD0R8HP374290Z" value="3746">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="5" default-label="Zwarcie do masy" stringResource-OID="SRs_X3WAMEIOH41QYKA80"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="1"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="31" hour="09" mileage="1016433.62" minute="21" month="07" operatinghour="" second="50" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="190" default-label="Prędkość obrotowa" stringResource-OID="SRs_XYV80CB8HLD1R6H7V"/>
                            <ip:data Value="484" unit="rpm"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3746" default-label="Highside - stopień końcow ukł recyrkulacji spalin (AGR)" stringResource-OID="SRs_XYNAD0R8HP374290Z"/>
                            <ip:data Value="0" unit="V"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Czujnik temperatury spalin przed obróbką końcową spalin" stringResource-OID="SRs_XG3MD0R8H78FA7QHF" value="3792">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="10" default-label="Przerwanie" stringResource-OID="SRs_XOBLHP7HH77LLS5Z4"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="31" hour="09" mileage="1016433.62" minute="20" month="07" operatinghour="" second="59" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3901" default-label="Nap. czujnika temp. spalin przed ukł. oczyszcz. spalin" stringResource-OID="SRs_XQMM2ZQ8HWSW3NTNX"/>
                            <ip:data Value="5" unit="V"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3885" default-label="Niefiltrowane ciśnienie doładowania" stringResource-OID="SRs_X6713ZQ8HWJWJY5CJ"/>
                            <ip:data Value="95" unit="kPa"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Odchylenie pozycji – zamknięty układ recyrkulacji spalin" stringResource-OID="SRs_XCCBD0R8HPDAQE22W" value="3850">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="31" hour="09" mileage="1016433.62" minute="20" month="07" operatinghour="" second="59" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3910" default-label="Wartość zadana układu recyrkulacji spalin" stringResource-OID="SRs_XSOL2ZQ8HKFQK9XJ7"/>
                            <ip:data Value="0" unit="%"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3911" default-label="Zaadaptowane położenie zaworu jako wartość stosunkowa" stringResource-OID="SRs_XXUID0R8HYHVRHDMZ"/>
                            <ip:data Value="100" unit="%"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Highside – stopień końcowy, zawór zamykający sprężone powietrze" stringResource-OID="SRs_XFCAD0R8HPYWGNL1S" value="3802">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="4" default-label="Brak sygnału" stringResource-OID="SRs_XFKLTIIOHW8NPT4HW"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="4"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="31" hour="09" mileage="1016433.62" minute="20" month="07" operatinghour="" second="59" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="190" default-label="Prędkość obrotowa" stringResource-OID="SRs_XYV80CB8HLD1R6H7V"/>
                            <ip:data Value="548" unit="rpm"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3802" default-label="Highside,stopień końc.,zawór odcin.sprężone powie." stringResource-OID="SRs_XNZ8TWP8H0H1AWYOH"/>
                            <ip:data Value="2" unit="V"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Moduł CAN 3" stringResource-OID="SRs_X0KFD0R8HDOY95V7L" value="3819">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="31" hour="09" mileage="1016433.62" minute="20" month="07" operatinghour="" second="59" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="190" default-label="Prędkość obrotowa" stringResource-OID="SRs_XYV80CB8HLD1R6H7V"/>
                            <ip:data Value="548" unit="rpm"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3095" default-label="Procentowa wartość ilości zadanej" stringResource-OID="SRs_XGMN2ZQ8H27661TDS"/>
                            <ip:data Value="16" unit="%"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Różnica ciśnienia spalin lub ciśnienie względne spalin" stringResource-OID="SRs_XD1MD0R8HS762N5F1" value="81">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="2" default-label="Potencjalnie możliwy błąd" stringResource-OID="SRs_XQUJREIOHU132A8UI"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="31" hour="09" mileage="1016433.62" minute="20" month="07" operatinghour="" second="59" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3885" default-label="Niefiltrowane ciśnienie doładowania" stringResource-OID="SRs_X6713ZQ8HWJWJY5CJ"/>
                            <ip:data Value="95" unit="kPa"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3883" default-label="Niefiltrowana różnica ciśnień spalin" stringResource-OID="SRs_XU6HD0R8HD35GNMLY"/>
                            <ip:data Value="36" unit="kPa"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Kontrola filtra cząstek stałych/katalizatora PM, różnica ciśnień spalin za wysoka lub za niska" stringResource-OID="SRs_XZ1SD0R8H1D375NRB" value="3785">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="31" hour="09" mileage="1016433.62" minute="20" month="07" operatinghour="" second="59" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="81" default-label="Różnica ciśnienia spalin lub ciśnienie względne spalin" stringResource-OID="SRs_XAOW2ZQ8HTNH9S3DN"/>
                            <ip:data Value="36" unit="kPa"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="102" default-label="Ciśnienie doładowania" stringResource-OID="SRs_XNH90CB8H1KQ8E0JG"/>
                            <ip:data Value="95" unit="kPa"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-ZBR2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25806.7070" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="INS-Inst-STON">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25807.7075" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="BRM-EBS2-Knorr">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81258087016" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="FWK-ECAS2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25811-7020" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
    </ip:KWP_ECUs>
</ip:DiagnosticMemory>