<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<ip:DiagnosticMemory xmlns:ip="http://man.eu/mancats3/diagnosespeicher" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" DataFormat="0001" FileType="Diagnosespeicher" schema-version="2.10" xsi:schemaLocation="http://man.eu/mancats3/trenddaten Diagnosespeicher.xsd">
    <ip:Header>
        <ip:MANcats-Version Value="V19_47_2"/>
        <ip:WID Value="WID33570"/>
        <ip:FP Value="030053ED"/>
        <ip:Timestamp day="15" hour="11" mileage="" minute="39" month="01" operatinghour="" second="47" year="2020"/>
    </ip:Header>
    <ip:VehicleInformation>
        <ip:LicensePlateNumber Value="Nicht eingetragen" default-label="Nummernschild" stringResource-OID="SRs_XYGMLB37HIUDZMQW5"/>
        <ip:NumberOfECUs Value="9"/>
        <ip:ShortVin Value="A233541" default-label="Kurze VIN" stringResource-OID="SRs_X66Z0JBEHLQ64B0JH"/>
        <ip:LongVin Value="WMAA23ZZ5BR009599" default-label="Lange Fahrgestellnummer" stringResource-OID="SRs_XJOD1JBEHQQETUTJL"/>
        <ip:VEC Value="Bus_mit_TEPS"/>
    </ip:VehicleInformation>
    <ip:KWP_ECUs>
        <ip:ECU AuthoringEcuName="FZG-ZBRO-CONTI">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-ZBR2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25806-7103" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="2">
                <ip:DTC default-label="Komunikat magistrali CAN – informacje – EBS" stringResource-OID="SRs_XUU0Q5D1HQ238925E00" value="6054">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="4"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="110"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="07" month="01" operatinghour="" second="56" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="14" month="01" operatinghour="" second="16" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Komunikat magistrali CAN – informacje – ECAS" stringResource-OID="SRs_X432Q5D1HH338925E00" value="6060">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="4"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="100"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="07" month="01" operatinghour="" second="56" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="14" month="01" operatinghour="" second="16" year="2020"/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="FWK-ECAS2-Wabco_Nachläufer">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25811-7021" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="1">
                <ip:DTC default-label="Przerwanie komunikacji magistrali CAN" stringResource-OID="SRs_XFYK1PS7HQGQX3PA2" value="3061">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="4" default-label="Brak sygnału" stringResource-OID="SRs_XFKLTIIOHW8NPT4HW"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="59"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="12" month="01" operatinghour="" second="13" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="14" month="01" operatinghour="" second="22" year="2020"/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="GTR-DIWA-Voith">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="36.25809-7058" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="1">
                <ip:DTC default-label="Elektryka/elektronika E300" stringResource-OID="SRs_X77A7B77H7Y8FAW5M" value="7001">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="9" default-label="Błąd urządzenia" stringResource-OID="SRs_X763RKIOH6Z9WWAAJ"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="3"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="45"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="07" month="01" operatinghour="" second="55" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="224" mileage="null" minute="177" month="00" operatinghour="" second="00" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-KSM-MAN">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25816.7005" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="1">
                <ip:DTC default-label="Magistrala danych CAN: przekroczenie czasu podczas odbioru dowolnie definiowanego komunikatu FREI_2." stringResource-OID="SRs_X7AVATS7HR1RH5KPL" value="3038">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="107"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="14" month="01" operatinghour="" second="25" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="0" default-label="Warunki otoczenia" stringResource-OID="SRs_XCFJGQSTH7GHWRI9E"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="190" default-label="Warunki otoczenia" stringResource-OID="SRs_XCFJGQSTH7GHWRI9E"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="8209" default-label="Warunki otoczenia" stringResource-OID="SRs_XCFJGQSTH7GHWRI9E"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="84" default-label="Warunki otoczenia" stringResource-OID="SRs_XCFJGQSTH7GHWRI9E"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="AKS-TuerMTS-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="36.25813-7005" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecorIdent.PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="BRM-EBS2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25808-7062" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="4">
                <ip:DTC default-label="Wyłącznik ciśnieniowy hamulca postojowego" stringResource-OID="SRs_XZGHQ8RSI1WFSDQ5" value="3556">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="3" default-label="Niezgodne" stringResource-OID="SRs_X5RRCKIOH0POKEJFU"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="121"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="17" hour="05" mileage="588210.94" minute="41" month="05" operatinghour="" second="42" year="2018"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Magistrala danych CAN układu przeniesienia napędu, magistrala wyłączona" stringResource-OID="SRs_XHZE8G7MHZMN0QBS3" value="3050">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="7" default-label="Zwarcie" stringResource-OID="SRs_XFCT5IIOHWBDVA38V"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="12" month="01" operatinghour="" second="59" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="(!) Przełącznik hamowania 1 lub 2" stringResource-OID="SRs_XR5H8G7MHE2R76Q1S" value="3018">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="10" default-label="Przerwanie" stringResource-OID="SRs_XOBLHP7HH77LLS5Z4"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="46"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="04" hour="01" mileage="765614.25" minute="55" month="12" operatinghour="" second="06" year="2019"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Błąd w regulacji ciśnienia podczas ostatniego cyklu włączania zapłonu" stringResource-OID="SRs_XIMH8G7MHE78OGVFZ" value="3530">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="08" month="01" operatinghour="" second="13" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-FFR-Conti">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25805-7086" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="MOT-EDC7C32-Bosch">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="51.25833-7092" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="2">
                <ip:DTC default-label="Zawór redukcyjny ciśnienia otwarty (zbyt wysokie ciśnienie)" stringResource-OID="SRs_XGVND0R8HJL8K79TS" value="3781">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="1"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="08" month="01" operatinghour="" second="25" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3897" default-label="Kickoff" stringResource-OID="SRs_XG8AD0R8H1XB8KC5M"/>
                            <ip:data Value="nieaktywne" unit=""/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="157" default-label="Ciśnienie paliwa w szynie paliwowej" stringResource-OID="SRs_XPXAD0R8HV7JCVMB"/>
                            <ip:data Value="75016" unit="kPa"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Czujnik ciśnienia paliwa (ciśnienie szyny paliwowej)" stringResource-OID="SRs_XV3JD0R8H1K9N88RR" value="3099">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="2" default-label="Potencjalnie możliwy błąd" stringResource-OID="SRs_XQUJREIOHU132A8UI"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="6" default-label="Zwarcie do Ubatt" stringResource-OID="SRs_XWQN6JIOH793PECQO"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="3"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="11" mileage="780910.25" minute="05" month="01" operatinghour="" second="58" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3895" default-label="Zarejestrowane napięcie czujnika ciśnienia paliwa" stringResource-OID="SRs_XI1S2ZQ8HZI98O7AM"/>
                            <ip:data Value="5" unit="V"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3691" default-label="Ekwiwalent prądu współczynnika trwania impulsu" stringResource-OID="SRs_XTVW2ZQ8HHP5Z6RCL"/>
                            <ip:data Value="2" unit="A"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
    </ip:KWP_ECUs>
    <ip:OBD_ECUs>
        <ip:ECU OBDEcuName="ECU_000">
            <ip:DTCs count="1">
                <ip:DTC default-label="&lt;no information available&gt;" value="0x2bad">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
    </ip:OBD_ECUs>
</ip:DiagnosticMemory>