<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<ip:DiagnosticMemory xmlns:ip="http://man.eu/mancats3/diagnosespeicher" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" DataFormat="0001" FileType="Diagnosespeicher" schema-version="2.10" xsi:schemaLocation="http://man.eu/mancats3/trenddaten Diagnosespeicher.xsd">
    <ip:Header>
        <ip:MANcats-Version Value="V20_02_B2"/>
        <ip:WID Value="WID33570"/>
        <ip:FP Value="030053ED"/>
        <ip:Timestamp day="24" hour="06" mileage="795644" minute="51" month="02" operatinghour="" second="41" year="2020"/>
    </ip:Header>
    <ip:VehicleInformation>
        <ip:LicensePlateNumber Value="Nicht eingetragen" default-label="Kfz-Kennzeichen" stringResource-OID="SRs_XYGMLB37HIUDZMQW5"/>
        <ip:NumberOfECUs Value="10"/>
        <ip:ShortVin Value="A233541" default-label="Kurze VIN" stringResource-OID="SRs_X66Z0JBEHLQ64B0JH"/>
        <ip:LongVin Value="WMAA23ZZ5BR009599" default-label="Lange Fahrgestellnummer" stringResource-OID="SRs_XJOD1JBEHQQETUTJL"/>
        <ip:VEC Value="Bus_mit_TEPS"/>
    </ip:VehicleInformation>
    <ip:KWP_ECUs>
        <ip:ECU AuthoringEcuName="FZG-ZBRO-CONTI">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="2">
                <ip:DTC default-label="Nieznany wpis do pamięci diagnostycznej" stringResource-OID="SRs_XN2Z3HZZI17WWXI8" value="0x1fb9">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="CONFIRMED-AND-PASSIVE" stringResource-OID="CONFIRMED-AND-PASSIVE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="no fault symptom available for DTC" stringResource-OID="no fault symptom available for DTC"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="1"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="27"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="18" hour="05" mileage="781433.75" minute="35" month="01" operatinghour="" second="55" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="1" default-label="Distance" stringResource-OID="Distance"/>
                            <ip:data Value="792394.94" unit="km"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Status – węzeł – numer błędu 2.8" stringResource-OID="SRs_XDCDTJV7HC6YQ1830" value="6128">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="CONFIRMED-AND-PASSIVE" stringResource-OID="CONFIRMED-AND-PASSIVE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="9" default-label="device error" stringResource-OID="device error"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="3"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="01" hour="06" mileage="787187.56" minute="46" month="02" operatinghour="" second="03" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="1" default-label="Distance" stringResource-OID="Distance"/>
                            <ip:data Value="787187.56" unit="km"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-FFR-Conti">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25805-7086" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="2">
                <ip:DTC default-label="Komunikat magistrali CAN – sygnał zatrzymania silnika" stringResource-OID="SRs_X8UJRGT6HBPQC3J2Q" value="3273">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany, ale nieaktualny" stringResource-OID="SRs_XPQR7X2SH67FFMKUF"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="11"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="21" hour="11" mileage="794508.25" minute="26" month="02" operatinghour="" second="06" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="84" default-label="Prędkość jazdy" stringResource-OID="SRs_XZ606DXMH3UPSLQTZ"/>
                            <ip:data Value="35" unit="km/h"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="190" default-label="Prędkość obrotowa" stringResource-OID="SRs_X92TAH5ZGO138925E00"/>
                            <ip:data Value="1118" unit="rpm"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Przełącznik zwalniacza, asystent przesunięcia" stringResource-OID="SRs_XOT2BDRNHLL9Z83OM" value="572">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany, ale nieaktualny" stringResource-OID="SRs_XPQR7X2SH67FFMKUF"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="3" default-label="Niezgodne" stringResource-OID="SRs_X5RRCKIOH0POKEJFU"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="27" hour="00" mileage="784979.56" minute="23" month="01" operatinghour="" second="58" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="84" default-label="Prędkość jazdy" stringResource-OID="SRs_XZ606DXMH3UPSLQTZ"/>
                            <ip:data Value="0" unit="km/h"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="190" default-label="Prędkość obrotowa" stringResource-OID="SRs_X92TAH5ZGO138925E00"/>
                            <ip:data Value="552" unit="rpm"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="BRM-EBS2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25808-7062" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="6">
                <ip:DTC default-label="Wyłącznik ciśnieniowy hamulca postojowego" stringResource-OID="SRs_XZGHQ8RSI1WFSDQ5" value="3556">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="3" default-label="Niezgodne" stringResource-OID="SRs_X5RRCKIOH0POKEJFU"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="121"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="17" hour="05" mileage="588210.94" minute="41" month="05" operatinghour="" second="42" year="2018"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="(!) Czujnik ciśnienia (oś tylna z lewej strony lub oś tylna) poza dopuszczalnym zakresem" stringResource-OID="SRs_XSBJ8G7MH2O92J12Z" value="3223">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="24" hour="03" mileage="795644.69" minute="50" month="02" operatinghour="" second="11" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Napięcie zasilające urządzenia sterującego (zacisk 15)" stringResource-OID="SRs_XQNG8G7MH5WR58485" value="3016">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="31"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="00" hour="255" mileage="21474836" minute="255" month="00" operatinghour="" second="63" year="1985"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Czujnik zużycia okładzin hamulcowych A (prawa oś dodatkowa) poza obowiązującym zakresem" stringResource-OID="SRs_XG3D8G7MH5X48KYU9" value="3371">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="5" default-label="Zwarcie do masy" stringResource-OID="SRs_X3WAMEIOH41QYKA80"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="30"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="21" hour="10" mileage="794466.19" minute="08" month="02" operatinghour="" second="02" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="(!) Przełącznik hamowania 1 lub 2" stringResource-OID="SRs_XR5H8G7MHE2R76Q1S" value="3018">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="10" default-label="Przerwanie" stringResource-OID="SRs_XOBLHP7HH77LLS5Z4"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="87"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="16" hour="07" mileage="780910.31" minute="13" month="01" operatinghour="" second="46" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Błąd w regulacji ciśnienia podczas ostatniego cyklu włączania zapłonu" stringResource-OID="SRs_XIMH8G7MHE78OGVFZ" value="3530">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="24" hour="06" mileage="795644.69" minute="19" month="02" operatinghour="" second="10" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="GTR-DIWA-Voith">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="36.25809-7058" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="4">
                <ip:DTC default-label="Mechanika skrzyni biegów" stringResource-OID="SRs_XNQ38B77HJX6L98JC" value="6507">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="9" default-label="Błąd urządzenia" stringResource-OID="SRs_X763RKIOH6Z9WWAAJ"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="16" hour="18" mileage="780915.25" minute="44" month="01" operatinghour="" second="21" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="160" mileage="null" minute="177" month="00" operatinghour="" second="00" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Mechanika skrzyni biegów" stringResource-OID="SRs_XMW08B77HAM5NPL7Y" value="6513">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="9" default-label="Błąd urządzenia" stringResource-OID="SRs_X763RKIOH6Z9WWAAJ"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="16" hour="19" mileage="792493.81" minute="12" month="02" operatinghour="" second="26" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="64" mileage="null" minute="177" month="00" operatinghour="" second="00" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Sygnał magistrali CAN hamulca przystankowego" stringResource-OID="SRs_X7SS8B77HV8HKY0G0" value="4713">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="3"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="4"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="27" hour="23" mileage="785421.75" minute="12" month="01" operatinghour="" second="42" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="32" mileage="null" minute="177" month="00" operatinghour="" second="00" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Komunikat magistrali CAN – informacje – sygnał wejściowy ABS" stringResource-OID="SRs_XTMB7B77HS7N8EHD5" value="4614">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="3"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="4"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="27" hour="23" mileage="785421.75" minute="12" month="01" operatinghour="" second="26" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="128" mileage="null" minute="177" month="00" operatinghour="" second="00" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="MOT-EDC7C32-Bosch">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="51.25833-7092" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="5">
                <ip:DTC default-label="Zawór redukcyjny ciśnienia otwarty (zbyt wysokie ciśnienie)" stringResource-OID="SRs_XGVND0R8HJL8K79TS" value="3781">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="1"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="33"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="20" hour="21" mileage="794308.06" minute="48" month="02" operatinghour="" second="30" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3897" default-label="Kickoff" stringResource-OID="SRs_XG8AD0R8H1XB8KC5M"/>
                            <ip:data Value="nieaktywne" unit=""/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="157" default-label="Ciśnienie paliwa w szynie paliwowej" stringResource-OID="SRs_XPXAD0R8HV7JCVMB"/>
                            <ip:data Value="75016" unit="kPa"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Czujnik ciśnienia paliwa (ciśnienie szyny paliwowej)" stringResource-OID="SRs_XV3JD0R8H1K9N88RR" value="3099">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="2" default-label="Potencjalnie możliwy błąd" stringResource-OID="SRs_XQUJREIOHU132A8UI"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="6" default-label="Zwarcie do Ubatt" stringResource-OID="SRs_XWQN6JIOH793PECQO"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="16" hour="07" mileage="780911.06" minute="55" month="01" operatinghour="" second="27" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3895" default-label="Zarejestrowane napięcie czujnika ciśnienia paliwa" stringResource-OID="SRs_XI1S2ZQ8HZI98O7AM"/>
                            <ip:data Value="5" unit="V"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3691" default-label="Ekwiwalent prądu współczynnika trwania impulsu" stringResource-OID="SRs_XTVW2ZQ8HHP5Z6RCL"/>
                            <ip:data Value="1" unit="A"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Pozostałe odchylenie regulacji układu recyrkulacji spalin regulowanego w zależności od położenia" stringResource-OID="SRs_XQYHD0R8H1AI1K1TA" value="3853">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="2" default-label="Potencjalnie możliwy błąd" stringResource-OID="SRs_XQUJREIOHU132A8UI"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="3"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="16" hour="08" mileage="780911.19" minute="10" month="01" operatinghour="" second="07" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3910" default-label="Wartość zadana układu recyrkulacji spalin" stringResource-OID="SRs_XSOL2ZQ8HKFQK9XJ7"/>
                            <ip:data Value="100" unit="%"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3911" default-label="Zaadaptowane położenie zaworu jako wartość stosunkowa" stringResource-OID="SRs_XXUID0R8HYHVRHDMZ"/>
                            <ip:data Value="0" unit="%"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Brak możliwości adaptacji sondy lambda" stringResource-OID="SRs_XA7ND0R8HJGOR7U28" value="3938">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="2" default-label="Potencjalnie możliwy błąd" stringResource-OID="SRs_XQUJREIOHU132A8UI"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="3"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="16" hour="19" mileage="780941.31" minute="36" month="01" operatinghour="" second="13" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3961" default-label="Współczynnik korekty do adapt. stęż. tlenu" stringResource-OID="SRs_XDDX2ZQ8H8T2XC5SM"/>
                            <ip:data Value="1" unit=""/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3959" default-label="Współcz trw imp do wysterow stopnia końcowego grzejnika" stringResource-OID="SRs_XV7FD0R8H1L7WEBSR"/>
                            <ip:data Value="141" unit="%"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Kontrola zbyt wysokiej wartości NOx (błąd MIL)" stringResource-OID="SRs_XC5CD0R8HGMSQXD5K" value="3929">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="27" hour="04" mileage="784983.81" minute="08" month="01" operatinghour="" second="20" year="2020"/>
                        <ip:uwb>
                            <ip:header Value="3952" default-label="Odchyłka lambda" stringResource-OID="SRs_X8YL2ZQ8H5KTPW3RR"/>
                            <ip:data Value="1" unit="s"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3970" default-label="Górna wartość graniczna odnośnie żądania MIL" stringResource-OID="SRs_XGBN2ZQ8HW2WYM2AD"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="INS-Inst-STON">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25807.7094" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="FWK-ECAS2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25811-7020" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="7">
                <ip:DTC default-label="Komunikat magistrali CAN – informacje – tachograf" stringResource-OID="SRs_XQQJ1PS7HK2GEW738" value="3081">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="4" default-label="Brak sygnału" stringResource-OID="SRs_XFKLTIIOHW8NPT4HW"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="26"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="20" hour="14" mileage="21474836" minute="38" month="02" operatinghour="" second="63" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="23" hour="20" mileage="795572.56" minute="07" month="02" operatinghour="" second="21" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Komunikat magistrali CAN – informacje – regulacja prędkości jazdy" stringResource-OID="SRs_XOFK1PS7HTD79MEBV" value="3062">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="4" default-label="Brak sygnału" stringResource-OID="SRs_XFKLTIIOHW8NPT4HW"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="3"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="23" hour="16" mileage="21474836" minute="32" month="02" operatinghour="" second="63" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="23" hour="20" mileage="795572.56" minute="07" month="02" operatinghour="" second="21" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Komunikat magistrali CAN – informacje – urządzenie sterujące silnikiem" stringResource-OID="SRs_XB8J1PS7HZS7SQB7R" value="3063">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="4" default-label="Brak sygnału" stringResource-OID="SRs_XFKLTIIOHW8NPT4HW"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="43"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="19" hour="23" mileage="21474836" minute="07" month="01" operatinghour="" second="63" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="23" hour="20" mileage="795572.56" minute="07" month="02" operatinghour="" second="21" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Komunikat magistrali CAN – informacje – przebieg w kilometrach" stringResource-OID="SRs_XUOJ1PS7HQ1IQWMF" value="3082">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="4" default-label="Brak sygnału" stringResource-OID="SRs_XFKLTIIOHW8NPT4HW"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="22"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="21" hour="20" mileage="21474836" minute="34" month="01" operatinghour="" second="63" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="21" hour="21" mileage="794749.12" minute="44" month="02" operatinghour="" second="57" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Komunikat magistrali CAN – informacje – ECAM" stringResource-OID="SRs_XL9K1PS7HBBOI3708" value="3066">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="4" default-label="Brak sygnału" stringResource-OID="SRs_XFKLTIIOHW8NPT4HW"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="18"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="21" hour="20" mileage="21474836" minute="34" month="01" operatinghour="" second="63" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="21" hour="21" mileage="21474836" minute="38" month="02" operatinghour="" second="63" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Komunikat magistrali CAN – informacje – czas/data" stringResource-OID="SRs_XXBJ1PS7H2VQ2C0AM" value="3070">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="4" default-label="Brak sygnału" stringResource-OID="SRs_XFKLTIIOHW8NPT4HW"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="18"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="21" hour="20" mileage="21474836" minute="34" month="01" operatinghour="" second="63" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="21" hour="21" mileage="794749.12" minute="44" month="02" operatinghour="" second="57" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Przerwanie komunikacji magistrali CAN" stringResource-OID="SRs_XFYK1PS7HQGQX3PA2" value="3061">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="4" default-label="Brak sygnału" stringResource-OID="SRs_XFKLTIIOHW8NPT4HW"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="20" hour="14" mileage="21474836" minute="38" month="02" operatinghour="" second="63" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="20" hour="14" mileage="794122.12" minute="41" month="02" operatinghour="" second="46" year="2020"/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-KSM-MAN">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25816.7005" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="AKS-TuerMTS-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="36.25813-7005" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecorIdent.PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="3">
                <ip:DTC default-label="Wyłącznik krańcowy zamknięty, przód / monitorowanie ciśnienia, drzwi 2" stringResource-OID="SRs_XG5FRIS8IPGVXAGQN" value="3181">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="CONFIRMED-AND-PASSIVE" stringResource-OID="CONFIRMED-AND-PASSIVE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="3" default-label="not plausible" stringResource-OID="not plausible"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="---"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="---"/>
                    </ip:Occurrence>
                </ip:DTC>
                <ip:DTC default-label="Wyłącznik krańcowy zamknięty, przód / monitorowanie ciśnienia, drzwi 4" stringResource-OID="SRs_XINIRIS8I1UBHTN10" value="3185">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="CONFIRMED-AND-PASSIVE" stringResource-OID="CONFIRMED-AND-PASSIVE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="3" default-label="not plausible" stringResource-OID="not plausible"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="---"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="---"/>
                    </ip:Occurrence>
                </ip:DTC>
                <ip:DTC default-label="Wyłącznik krańcowy zamknięty, przód / monitorowanie ciśnienia, drzwi 3" stringResource-OID="SRs_XW4IRIS8I1LH6PZ49" value="3183">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="CONFIRMED-AND-PASSIVE" stringResource-OID="CONFIRMED-AND-PASSIVE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="3" default-label="not plausible" stringResource-OID="not plausible"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="---"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="---"/>
                    </ip:Occurrence>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-ZBR2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25806-7103" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="4">
                <ip:DTC default-label="Włącznik świateł" stringResource-OID="SRs_XI2DQ5D1HQ938925E00" value="4000">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="10" default-label="Przerwanie" stringResource-OID="SRs_XOBLHP7HH77LLS5Z4"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="6"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="16" hour="20" mileage="780951.62" minute="14" month="01" operatinghour="" second="47" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="20" hour="09" mileage="794017" minute="00" month="02" operatinghour="" second="05" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Światło hamowania ciągnika" stringResource-OID="SRs_XTDWR5D1HQ538925E00" value="3502">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="17" hour="05" mileage="781060.75" minute="41" month="01" operatinghour="" second="38" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="29" hour="23" mileage="786303.69" minute="07" month="01" operatinghour="" second="25" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Prawe światło mijania" stringResource-OID="SRs_X5TKQ5D1H8E38925E00" value="4002">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="12" default-label="Przerwanie lub zwarcie do Ubat" stringResource-OID="SRs_XYQ2SIIOHQ5F1E9YA"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="4"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="19" hour="16" mileage="782098.38" minute="39" month="01" operatinghour="" second="46" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="19" hour="23" mileage="782248.31" minute="10" month="01" operatinghour="" second="51" year="2020"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Lewe światło mijania" stringResource-OID="SRs_XNK9S5D1H8D38925E00" value="4001">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="12" default-label="Przerwanie lub zwarcie do Ubat" stringResource-OID="SRs_XYQ2SIIOHQ5F1E9YA"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="7"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="04" hour="23" mileage="788071.12" minute="03" month="02" operatinghour="" second="08" year="2020"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="05" hour="18" mileage="788396.5" minute="44" month="02" operatinghour="" second="41" year="2020"/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
    </ip:KWP_ECUs>
    <ip:OBD_ECUs>
        <ip:ECU OBDEcuName="ECU_000">
            <ip:DTCs count="4">
                <ip:DTC default-label="OEM specific DTC" value="P1071">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
                <ip:DTC default-label="OEM specific DTC" value="P1048">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
                <ip:DTC default-label="Fuel Rail Pressure Sensor A Circuit" value="P0190">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
                <ip:DTC default-label="&lt;no information available&gt;" value="0x2bad">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
    </ip:OBD_ECUs>
</ip:DiagnosticMemory>
