<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<ip:DiagnosticMemory xmlns:ip="http://man.eu/mancats3/diagnosespeicher" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" DataFormat="0001" FileType="Diagnosespeicher" schema-version="2.10" xsi:schemaLocation="http://man.eu/mancats3/trenddaten Diagnosespeicher.xsd">
    <ip:Header>
        <ip:MANcats-Version Value="V21_16P"/>
        <ip:WID Value="WID33570"/>
        <ip:FP Value="030053ED"/>
        <ip:Timestamp day="05" hour="07" mileage="1124505" minute="42" month="06" operatinghour="" second="08" year="2021"/>
    </ip:Header>
    <ip:VehicleInformation>
        <ip:LicensePlateNumber Value="1117" default-label="Kfz-Kennzeichen" stringResource-OID="SRs_XYGMLB37HIUDZMQW5"/>
        <ip:NumberOfECUs Value="10"/>
        <ip:ShortVin Value="A233974" default-label="Kurze VIN" stringResource-OID="SRs_X66Z0JBEHLQ64B0JH"/>
        <ip:LongVin Value="WMAA23ZZ7BR009152" default-label="Lange Fahrgestellnummer" stringResource-OID="SRs_XJOD1JBEHQQETUTJL"/>
        <ip:VEC Value="Bus_mit_TEPS"/>
    </ip:VehicleInformation>
    <ip:KWP_ECUs>
        <ip:ECU AuthoringEcuName="AKS-TuerMTS-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="36.25813-7005" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecorIdent.PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="2">
                <ip:DTC default-label="Wyłącznik krańcowy zamknięty, przód / monitorowanie ciśnienia, drzwi 1" stringResource-OID="SRs_XGZHRIS8IDIFZ3X7W" value="3179">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="CONFIRMED-AND-PASSIVE" stringResource-OID="CONFIRMED-AND-PASSIVE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="3" default-label="not plausible" stringResource-OID="not plausible"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="---"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="---"/>
                    </ip:Occurrence>
                </ip:DTC>
                <ip:DTC default-label="Wyłącznik krańcowy zamknięty, przód / monitorowanie ciśnienia, drzwi 2" stringResource-OID="SRs_XG5FRIS8IPGVXAGQN" value="3181">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="CONFIRMED-AND-PASSIVE" stringResource-OID="CONFIRMED-AND-PASSIVE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="3" default-label="not plausible" stringResource-OID="not plausible"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="---"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="---"/>
                    </ip:Occurrence>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="BRM-EBS2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25808-7062" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="3">
                <ip:DTC default-label="(!) Przełącznik hamowania 1 lub 2" stringResource-OID="SRs_XR5H8G7MHE2R76Q1S" value="3018">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="10" default-label="Przerwanie" stringResource-OID="SRs_XOBLHP7HH77LLS5Z4"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="121"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="06" hour="05" mileage="1102984.88" minute="00" month="04" operatinghour="" second="01" year="2021"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Napięcie zasilające urządzenia sterującego (zacisk 15)" stringResource-OID="SRs_XQNG8G7MH5WR58485" value="3016">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="3"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="03" mileage="1106183.62" minute="22" month="04" operatinghour="" second="12" year="2021"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Błąd w regulacji ciśnienia podczas ostatniego cyklu włączania zapłonu" stringResource-OID="SRs_XIMH8G7MHE78OGVFZ" value="3530">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="3" default-label="Błąd jest aktualny i został zapisany" stringResource-OID="SRs_XSZLVEIOH47QXL9WO"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="05" hour="06" mileage="1124505.12" minute="25" month="06" operatinghour="" second="16" year="2021"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="MOT-EDC7C32-Bosch">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="51.25803-7882" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="4">
                <ip:DTC default-label="Highside - stopień końcow ukł recyrkulacji spalin (AGR)" stringResource-OID="SRs_XYNAD0R8HP374290Z" value="3746">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="2" default-label="Potencjalnie możliwy błąd" stringResource-OID="SRs_XQUJREIOHU132A8UI"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="5" default-label="Zwarcie do masy" stringResource-OID="SRs_X3WAMEIOH41QYKA80"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="05" hour="09" mileage="1102947.12" minute="56" month="04" operatinghour="" second="30" year="2021"/>
                        <ip:uwb>
                            <ip:header Value="190" default-label="Prędkość obrotowa" stringResource-OID="SRs_XYV80CB8HLD1R6H7V"/>
                            <ip:data Value="0" unit="rpm"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3746" default-label="Highside - stopień końcow ukł recyrkulacji spalin (AGR)" stringResource-OID="SRs_XYNAD0R8HP374290Z"/>
                            <ip:data Value="0" unit="V"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Kontrola zbyt wysokiej wartości NOx (błąd MIL)" stringResource-OID="SRs_XC5CD0R8HGMSQXD5K" value="3929">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="2" default-label="Potencjalnie możliwy błąd" stringResource-OID="SRs_XQUJREIOHU132A8UI"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="9" default-label="Błąd urządzenia" stringResource-OID="SRs_X763RKIOH6Z9WWAAJ"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="05" hour="09" mileage="1102947.12" minute="56" month="04" operatinghour="" second="30" year="2021"/>
                        <ip:uwb>
                            <ip:header Value="3952" default-label="Odchyłka lambda" stringResource-OID="SRs_X8YL2ZQ8H5KTPW3RR"/>
                            <ip:data Value="65024" unit="s"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3970" default-label="Górna wartość graniczna odnośnie żądania MIL" stringResource-OID="SRs_XGBN2ZQ8HW2WYM2AD"/>
                            <ip:data Value="3" unit=""/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Kontrola filtra cząstek stałych/katalizatora PM, różnica ciśnień spalin za wysoka lub za niska" stringResource-OID="SRs_XZ1SD0R8H1D375NRB" value="3785">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="2" default-label="Potencjalnie możliwy błąd" stringResource-OID="SRs_XQUJREIOHU132A8UI"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="29" hour="06" mileage="1111314.75" minute="16" month="04" operatinghour="" second="01" year="2021"/>
                        <ip:uwb>
                            <ip:header Value="81" default-label="Różnica ciśnienia spalin lub ciśnienie względne spalin" stringResource-OID="SRs_XAOW2ZQ8HTNH9S3DN"/>
                            <ip:data Value="4" unit="kPa"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="102" default-label="Ciśnienie doładowania" stringResource-OID="SRs_XNH90CB8H1KQ8E0JG"/>
                            <ip:data Value="95" unit="kPa"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Czujnik różnicy ciśnienia lub ciśn. względnego spalin" stringResource-OID="SRs_XIGQD0R8H13GKRDXU" value="3789">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="1" default-label="Zbyt wysoki" stringResource-OID="SRs_XFEUIKIOH4SOI7GSR"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="04" hour="22" mileage="1124505.12" minute="00" month="06" operatinghour="" second="45" year="2021"/>
                        <ip:uwb>
                            <ip:header Value="3885" default-label="Niefiltrowane ciśnienie doładowania" stringResource-OID="SRs_X6713ZQ8HWJWJY5CJ"/>
                            <ip:data Value="95" unit="kPa"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="3899" default-label="Zarejestrowane napięcie czujnika różnicy ciśnień spalin lub czujnika ciśnienia względnego spalin" stringResource-OID="SRs_XOZAD0R8HP837SJN4"/>
                            <ip:data Value="1" unit="V"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="FWK-ECAS2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25811-7020" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="1">
                <ip:DTC default-label="Czujnik drogi – oś przednia/oś środkowa" stringResource-OID="SRs_X03K1PS7HE8F2AL7F" value="3103">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="10" default-label="Przerwanie" stringResource-OID="SRs_XOBLHP7HH77LLS5Z4"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="04" hour="17" mileage="1124505.12" minute="35" month="06" operatinghour="" second="59" year="2021"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="04" hour="17" mileage="1124505.12" minute="36" month="06" operatinghour="" second="06" year="2021"/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="FZG-ZBRO-CONTI">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="3">
                <ip:DTC default-label="Nieznany wpis do pamięci diagnostycznej" stringResource-OID="SRs_XN2Z3HZZI17WWXI8" value="0x1fb9">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="CONFIRMED-AND-PASSIVE" stringResource-OID="CONFIRMED-AND-PASSIVE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="no fault symptom available for DTC" stringResource-OID="no fault symptom available for DTC"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="1"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="126"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="06" hour="05" mileage="1102986.12" minute="02" month="04" operatinghour="" second="35" year="2021"/>
                        <ip:uwb>
                            <ip:header Value="1" default-label="Distance" stringResource-OID="Distance"/>
                            <ip:data Value="1123729.25" unit="km"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Awaria drzwi" stringResource-OID="SRs_XC0SSJV7H05V1P5JG" value="4673">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="CONFIRMED-AND-PASSIVE" stringResource-OID="CONFIRMED-AND-PASSIVE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="no fault symptom available for DTC" stringResource-OID="no fault symptom available for DTC"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="1"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="72"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="06" hour="08" mileage="1103062.38" minute="08" month="04" operatinghour="" second="50" year="2021"/>
                        <ip:uwb>
                            <ip:header Value="1" default-label="Distance" stringResource-OID="Distance"/>
                            <ip:data Value="1121930" unit="km"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Błąd HLK" stringResource-OID="SRs_XZ17SJV7HRJJIQ8PW" value="5402">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="CONFIRMED-AND-PASSIVE" stringResource-OID="CONFIRMED-AND-PASSIVE"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="9" default-label="device error" stringResource-OID="device error"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="3"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="119"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="06" hour="09" mileage="21474836" minute="11" month="04" operatinghour="" second="50" year="2021"/>
                        <ip:uwb>
                            <ip:header Value="1" default-label="Distance" stringResource-OID="Distance"/>
                            <ip:data Value="1124082" unit="km"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-KSM-MAN">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25816.7005" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="1">
                <ip:DTC default-label="Magistrala danych CAN: przekroczenie czasu przy odbiorze dowolnie definiowanego komunikatu FREI_3." stringResource-OID="SRs_XF9VATS7HC18T87J9" value="3039">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="0" default-label="Brak dostępnego symptomu dla tego SPN" stringResource-OID="SRs_X5T5WEIOHE7NYZ9EK"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="1"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="15" hour="09" mileage="1106183.75" minute="03" month="04" operatinghour="" second="57" year="2021"/>
                        <ip:uwb>
                            <ip:header Value="0" default-label="Warunki otoczenia" stringResource-OID="SRs_XCFJGQSTH7GHWRI9E"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="190" default-label="Warunki otoczenia" stringResource-OID="SRs_XCFJGQSTH7GHWRI9E"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="28688" default-label="Warunki otoczenia" stringResource-OID="SRs_XCFJGQSTH7GHWRI9E"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                        <ip:uwb>
                            <ip:header Value="84" default-label="Warunki otoczenia" stringResource-OID="SRs_XCFJGQSTH7GHWRI9E"/>
                            <ip:data Value="0" unit=""/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-ZBR2-Wabco">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25806-7096" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="7">
                <ip:DTC default-label="Czujnik ciśnienia (ciśnienie zapasowe obwód 3)" stringResource-OID="SRs_XXE6S5D1HHB38925E00" value="1086">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="3"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="06" hour="08" mileage="1103062.38" minute="10" month="04" operatinghour="" second="05" year="2021"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="16" hour="14" mileage="1106447.5" minute="54" month="04" operatinghour="" second="31" year="2021"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Włącznik świateł" stringResource-OID="SRs_XI2DQ5D1HQ938925E00" value="4000">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="10" default-label="Przerwanie" stringResource-OID="SRs_XOBLHP7HH77LLS5Z4"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="33"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="06" hour="16" mileage="1103248" minute="15" month="04" operatinghour="" second="18" year="2021"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="03" hour="07" mileage="1124082" minute="08" month="06" operatinghour="" second="03" year="2021"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Czujnik ciśnienia (ciśnienie zapasowe obwód 4)" stringResource-OID="SRs_XEXYR5D1H8738925E00" value="1089">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="1"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="3"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="08" hour="05" mileage="1103843.75" minute="59" month="04" operatinghour="" second="34" year="2021"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="16" hour="21" mileage="1106603.12" minute="25" month="04" operatinghour="" second="57" year="2021"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Lewe światło mijania" stringResource-OID="SRs_XNK9S5D1H8D38925E00" value="4001">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="12" default-label="Przerwanie lub zwarcie do Ubat" stringResource-OID="SRs_XYQ2SIIOHQ5F1E9YA"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="3"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="20" hour="03" mileage="1119374.62" minute="41" month="05" operatinghour="" second="14" year="2021"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="21" hour="03" mileage="1119794.12" minute="21" month="05" operatinghour="" second="53" year="2021"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Ciśnienie oleju silnikowego" stringResource-OID="SRs_XSRZR5D1HQ738925E00" value="100">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="4"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="25" hour="05" mileage="1120692.25" minute="35" month="05" operatinghour="" second="24" year="2021"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="25" hour="05" mileage="1120692.62" minute="35" month="05" operatinghour="" second="55" year="2021"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Światło hamowania ciągnika" stringResource-OID="SRs_XTDWR5D1HQ538925E00" value="3502">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="2" default-label="Za niski" stringResource-OID="SRs_XVXOKKIOHMSVJN4SP"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="22"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="27" hour="08" mileage="1121598.12" minute="58" month="05" operatinghour="" second="11" year="2021"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="28" hour="00" mileage="1121827.38" minute="35" month="05" operatinghour="" second="04" year="2021"/>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Blokada kabiny kierowcy" stringResource-OID="SRs_XNIYR5D1HZ638925E00" value="5600">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany" stringResource-OID="SRs_X3ENDJIOHOBN2WLYB"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="6" default-label="Zwarcie do Ubatt" stringResource-OID="SRs_XWQN6JIOH793PECQO"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="1"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="04" hour="10" mileage="1124505.12" minute="27" month="06" operatinghour="" second="19" year="2021"/>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="04" hour="10" mileage="1124505.12" minute="28" month="06" operatinghour="" second="11" year="2021"/>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="ZTR-FFR-Conti">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25805-7086" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
            <ip:DTCs count="3">
                <ip:DTC default-label="Sprzęgło wentylatora" stringResource-OID="SRs_XWR4BDRNH43QBGAE8" value="647">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany, ale nieaktualny" stringResource-OID="SRs_XPQR7X2SH67FFMKUF"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="10" default-label="Przerwanie" stringResource-OID="SRs_XOBLHP7HH77LLS5Z4"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="2"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="2"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="04" hour="01" mileage="1113306.5" minute="12" month="05" operatinghour="" second="48" year="2021"/>
                        <ip:uwb>
                            <ip:header Value="84" default-label="Prędkość jazdy" stringResource-OID="SRs_XZ606DXMH3UPSLQTZ"/>
                            <ip:data Value="0" unit="km/h"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="190" default-label="Prędkość obrotowa" stringResource-OID="SRs_X92TAH5ZGO138925E00"/>
                            <ip:data Value="0" unit="rpm"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Przełącznik ograniczenia maksymalnej prędkości" stringResource-OID="SRs_XEC2BDRNHAH1YP20H" value="898">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany, ale nieaktualny" stringResource-OID="SRs_XPQR7X2SH67FFMKUF"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="3" default-label="Niezgodne" stringResource-OID="SRs_X5RRCKIOH0POKEJFU"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="5"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="38"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="31" hour="13" mileage="1123265" minute="35" month="05" operatinghour="" second="25" year="2021"/>
                        <ip:uwb>
                            <ip:header Value="84" default-label="Prędkość jazdy" stringResource-OID="SRs_XZ606DXMH3UPSLQTZ"/>
                            <ip:data Value="0" unit="km/h"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="190" default-label="Prędkość obrotowa" stringResource-OID="SRs_X92TAH5ZGO138925E00"/>
                            <ip:data Value="550" unit="rpm"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
                <ip:DTC default-label="Sygnał temperatury powietrza doładowującego" stringResource-OID="SRs_XENJUGT6HTGVRK7V1" value="3117">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Błąd zapisany, ale nieaktualny" stringResource-OID="SRs_XPQR7X2SH67FFMKUF"/>
                    </ip:Status>
                    <ip:FMI>
                        <ip:header default-label="FMI" stringResource-OID="SRs_XUTM9NL8H8BKPTDO5"/>
                        <ip:data Value="8" default-label="Błędny sygnał" stringResource-OID="SRs_X94GFKIOHOP6ESACI"/>
                    </ip:FMI>
                    <ip:Priority>
                        <ip:header default-label="Priorytet" stringResource-OID="SRs_X5AH2JEEH54S2LBV"/>
                        <ip:data Value="4"/>
                    </ip:Priority>
                    <ip:Occurrence>
                        <ip:header default-label="Częstotliwość" stringResource-OID="SRs_X7AB9IIOHACFFHR9N"/>
                        <ip:data Value="3"/>
                    </ip:Occurrence>
                    <ip:envData>
                        <ip:Timestamp day="25" hour="05" mileage="1120692.38" minute="35" month="05" operatinghour="" second="33" year="2021"/>
                        <ip:uwb>
                            <ip:header Value="84" default-label="Prędkość jazdy" stringResource-OID="SRs_XZ606DXMH3UPSLQTZ"/>
                            <ip:data Value="38" unit="km/h"/>
                        </ip:uwb>
                    </ip:envData>
                    <ip:envData>
                        <ip:Timestamp day="" hour="" mileage="null" minute="" month="00" operatinghour="" second="" year=""/>
                        <ip:uwb>
                            <ip:header Value="190" default-label="Prędkość obrotowa" stringResource-OID="SRs_X92TAH5ZGO138925E00"/>
                            <ip:data Value="1204" unit="rpm"/>
                        </ip:uwb>
                    </ip:envData>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="INS-Inst-STON">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25807.7094" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
        <ip:ECU AuthoringEcuName="FWK-ECAS2-Wabco_Nachläufer">
            <ip:Identifications count="1">
                <ip:Identifikation LID_DID="0x91" Value="81.25811-7021" default-label="Numer rzeczowy MAN" fullyQualifiedShortNamePath="Vehicle Manufacturer ECU Hardware Number#PA_DataRecor.PA_VehicManufECUHardwNumbe" stringResource-OID="SRs_XCQB4B8EHJ3HM1T72"/>
            </ip:Identifications>
        </ip:ECU>
    </ip:KWP_ECUs>
    <ip:OBD_ECUs>
        <ip:ECU OBDEcuName="ECU_000">
            <ip:DTCs count="4">
                <ip:DTC default-label="OEM specific DTC" value="P1522">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
                <ip:DTC default-label="OEM specific DTC" value="P1037">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
                <ip:DTC default-label="&lt;no information available&gt;" value="0x2bac">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
                <ip:DTC default-label="&lt;no information available&gt;" value="0x2bad">
                    <ip:Status>
                        <ip:header default-label="Status" stringResource-OID="SRs_XUWYAML8H1YGJXQPQ"/>
                        <ip:data Value="1" default-label="Confirmed-and-Passive" stringResource-OID="SRs_XEU8AJ2FHG8B6XUXA"/>
                    </ip:Status>
                    <ip:Class>
                        <ip:header default-label="" stringResource-OID=""/>
                        <ip:data Value="" default-label="" stringResource-OID=""/>
                    </ip:Class>
                </ip:DTC>
            </ip:DTCs>
        </ip:ECU>
    </ip:OBD_ECUs>
</ip:DiagnosticMemory>